Our solar power inverter offers concern to sun oriented power usage to save money on power bills. It charges the battery from both solar panel and grid. In the event that Sun power is accessible then the battery charged through sun powered Panel. In case, solar is not accessible then inverter charges battery through grid and mains. The battery can be charged and provide solar energy to associated load if sun oriented formation is adequate else it provides first concern to sunlight based battery charging and afterward provide extra energy to associated loads.
At the point when power provide by means of the lattice of the electric use is unrealistic, desirable or economic, our solar power inverters can be introduced monetarily as one system. There is awesome potential for the usage of single system in progressing nations, where vast sections of the nation frequently stay without power supply. Further, in single system, the power storage in the collectors as well as the operation of various customers is acknowledged utilizing direct voltage. This provides them a chance to characterize and have the coveted reinforcement relying on their demand by utilizing batteries.
The aim of our company is to provide stand-alone inverter to fulfill the demands of various loads and customers. Our inverter is widely utilized in wide range of areas such as domestic appliances, industrial machines, sensitive electronic instruments in communications and so on.
Highlights:
Technical Specification:
Model | SDP-20KW | |
Isolation | Low Frequency Transformer | |
DC Input | Input rated voltage(VDC) | 220V |
Input rated current(A) | 90.9A | |
AC Input | Rated AC output power | 20KW |
AC output waveform | Pure sine wave | |
Phases | Three-Phase | |
Output rated voltage | 380VAC 3% | |
Output Frequency | 50Hz/60Hz 0.05Hz | |
Output rated current(phase) | 30.3A | |
Structure | Charging function | Charger outside (optional) |
Power Factor(PF) | 0.8 | |
Overload Ability | 150%, 10s | |
Inverter efficiency (80% resistive load) | 92% | |
Waveform distortion rate (THD) | <3%(Linear load) | |
Crest Factor (CF) | 3:1 | |
Electrical insulation properties | 1500Vac, 1 Minute | |
Ambient temperature | -15~+55 C | |
Using environment humidity | 0~90% No condensation | |
Protection | Input reverse,Input under voltage, overvoltage, over temperature, over-current, short circuit, etc. | |
Cooling method | Fan-cooled | |
Noise | <55dB | |
Degree of protection | IP20(indoor) | |
Using altitude(m) | <2000 | |
CE Standard | EN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000 |